Printable EPA 608 Core Practice Test with Answer Key

Answer each question, then use the key at the end to check your work. This is an independent practice set, not an official certification test.

Last reviewed: November 24, 2026

  1. Which refrigerant was the likely substitute for CFC-12 (R-12) in small appliances?

    1. HFC-134a
    2. R-22
    3. R-11
    4. R-123
  2. Why should oxygen or compressed air never be used to leak test a refrigeration system?

    1. They are too expensive
    2. They condense too easily
    3. They are heavier than refrigerant
    4. They can react explosively with oil under pressure
  3. Which of the following releases is permitted under the venting prohibition?

    1. De minimis releases while making good-faith attempts to recover, such as when connecting or disconnecting hoses
    2. Venting refrigerant to save recovery time
    3. Venting a system before disposal if it holds under 5 lb
    4. Venting HFCs because they don't deplete ozone
  4. System-dependent recovery equipment may NOT be used on appliances with a full charge of more than:

    1. 200 pounds
    2. 50 pounds
    3. 15 pounds
    4. 5 pounds
  5. Which of the 'three Rs' requires chemical analysis to verify purity?

    1. Reclaim
    2. Recover
    3. Recycle
    4. All three
  6. After passing through the metering device, refrigerant enters the evaporator as a:

    1. High-pressure liquid
    2. High-pressure superheated vapor
    3. Low-pressure mixture of liquid and vapor
    4. Subcooled high-pressure liquid
  7. A system has just been opened for a major repair. Before charging, the technician must:

    1. Charge immediately
    2. Leak test, then evacuate to remove air and moisture
    3. Add oxygen
    4. Only replace the drier
  8. How does the valve outlet on most A2L disposable cylinders differ from an A1 cylinder?

    1. It uses a quick-connect coupler
    2. It has a left-hand thread
    3. It has no outlet; it is filled through a stub
    4. It has a right-hand thread like A1
  9. Why do CFCs reach the stratosphere instead of breaking down near the ground?

    1. They are very stable in the lower atmosphere
    2. They are destroyed by rain
    3. They react quickly with water vapor
    4. They are lighter than helium
  10. Before disposing of a disposable refrigerant cylinder, you should:

    1. Recover the remaining refrigerant to 0 psig, then render the cylinder useless (for example, puncture it) and recycle the metal
    2. Throw it away with the valve closed and refrigerant inside
    3. Refill it with nitrogen
    4. Return it to EPA
  11. Fractionation is:

    1. Oil separating from refrigerant in the compressor
    2. Blend components leaking or evaporating at different rates, changing the blend composition
    3. Mixing two different refrigerants in a cylinder
    4. Refrigerant breaking down from heat
  12. A refrigerant cylinder should never be heated with:

    1. A heated blanket designed for cylinders
    2. Warm water
    3. An open flame or torch
    4. Ambient air
  13. Clean Air Act civil penalties for refrigerant violations are assessed:

    1. Per day, per violation
    2. Only on the first violation
    3. Once per year
    4. Only after three warnings
  14. Which equipment is covered by the Section 608 rule?

    1. Only equipment over 50 pounds
    2. All stationary air-conditioning and refrigeration equipment containing CFCs, HCFCs or non-exempt substitutes (MVACs are covered under Section 609)
    3. Only commercial chillers
    4. Only residential equipment
  15. Reclaimers may release no more than what percentage of refrigerant during the reclamation process?

    1. 5%
    2. 1.5%
    3. 0.5%
    4. 10%
  16. In a vapor-compression system, refrigerant leaves the compressor as a:

    1. High-pressure, high-temperature vapor
    2. Low-pressure vapor
    3. Subcooled liquid
    4. Low-pressure liquid
  17. Using shorter, larger-diameter hoses during recovery generally:

    1. Speeds recovery
    2. Slows recovery
    3. Contaminates the refrigerant
    4. Has no effect
  18. Ammonia (R-717) is classified as:

    1. A3
    2. A1
    3. B2L
    4. B1
  19. R-22 belongs to which refrigerant family?

    1. HFC
    2. HCFC
    3. CFC
    4. HFO
  20. Disposable refrigerant cylinders:

    1. May be refilled with recovered refrigerant
    2. Must never be refilled
    3. Can be used for nitrogen
    4. May be refilled once
  21. Why can't you simply add an HFC refrigerant to a system that contains mineral oil?

    1. HFCs require a higher voltage
    2. Mineral oil freezes HFCs
    3. Many substitute refrigerants are not compatible with lubricants used with CFCs and HCFCs
    4. HFCs are flammable
  22. Minimum personal protective equipment when handling refrigerant includes:

    1. Earplugs only
    2. A dust mask only
    3. Nothing if outdoors
    4. Safety glasses/goggles and gloves
  23. Who can be fined for violating the Clean Air Act refrigerant rules?

    1. Only equipment owners
    2. Only certifying organizations
    3. Any person, including technicians, who violates the rules
    4. Only refrigerant wholesalers
  24. Which certification type covers servicing or disposing of high- and very high-pressure appliances (except small appliances and MVACs)?

    1. Type II
    2. Core only
    3. Type III
    4. Type I
  25. Who may reclaim refrigerant for sale to a new owner?

    1. Any wholesaler
    2. Any certified technician
    3. The equipment owner
    4. A reclaimer certified with EPA that meets the AHRI 700 specifications
  1. A. HFC-134a (Substitute refrigerants & oils)

    EPA's Type I test topics name HFC-134a (R-134a) as the likely substitute for CFC-12 (R-12).

    Source: EPA – Section 608 Test Topics

  2. D. They can react explosively with oil under pressure (Safety)

    Oxygen and compressed air can combine with oil under pressure and explode. Dry nitrogen is inert.

    Source: EPA – Section 608 Test Topics

  3. A. De minimis releases while making good-faith attempts to recover, such as when connecting or disconnecting hoses (Clean Air Act & Montreal Protocol)

    EPA allows 'de minimis' releases that occur while making good-faith attempts to recapture refrigerant, including when connecting or disconnecting hoses, plus normal operating leaks and releases of exempt substitutes.

    Source: EPA – Prohibition on Venting Refrigerants

  4. C. 15 pounds (Section 608 regulations)

    40 CFR 82.156(e): system-dependent recovery equipment may not be used on appliances with a full charge of more than 15 pounds unless it is permanently attached as a pump-out unit.

    Source: 40 CFR 82.156(e) – Required practices for evacuation and recovery

  5. A. Reclaim (The three Rs: recover, recycle, reclaim)

    Only reclamation requires verifying each batch against the AHRI 700 specifications through analysis.

    Source: EPA – Refrigerant Reclamation Requirements

  6. C. Low-pressure mixture of liquid and vapor (Refrigeration cycle & gauges)

    The metering device drops pressure, and some liquid flashes to vapor, so a low-pressure liquid/vapor mixture enters the evaporator.

    Source: EPA – Section 608 Test Topics

  7. B. Leak test, then evacuate to remove air and moisture (Recovery & dehydration)

    After repair: leak test (with nitrogen), then evacuate to remove non-condensables and moisture, then charge.

    Source: EPA – Section 608 Test Topics

  8. B. It has a left-hand thread (A2L, A3 & low-GWP refrigerants)

    Manufacturers moved A2L cylinders to a left-hand-thread outlet to prevent cross-contamination with A1 refrigerants. An adapter is needed for hoses with standard right-hand fittings.

    Source: Arkema Forane – A2L vs A1 cylinders

  9. A. They are very stable in the lower atmosphere (Ozone depletion & environmental impact)

    CFCs are very stable in the troposphere, so they last long enough to migrate to the stratosphere, where strong UV light breaks them apart and releases chlorine.

    Source: EPA – Section 608 Test Topics

  10. A. Recover the remaining refrigerant to 0 psig, then render the cylinder useless (for example, puncture it) and recycle the metal (Shipping & cylinders)

    Recover what's left in an empty disposable cylinder (at least to 0 psig), then mark it empty and render it unusable before scrap recycling. Never refill it. Note: from January 1, 2028, 40 CFR 84.116 requires disposable cylinders with an HFC heel to go to a reclaimer or other entity that removes the heel, or to be evacuated by a certified technician to 15 inches Hg vacuum with a signed statement.

    Source: EPA – Section 608 Test Topics

  11. B. Blend components leaking or evaporating at different rates, changing the blend composition (Substitute refrigerants & oils)

    Fractionation is the tendency of different components of a blend to leak or vaporize at different rates, changing the composition of what remains in the system.

    Source: EPA – Section 608 Test Topics

  12. C. An open flame or torch (Safety)

    Never use an open flame or direct torch heat on a cylinder; it can over-pressurize and rupture the cylinder or decompose the refrigerant.

    Source: EPA – Section 608 Test Topics

  13. A. Per day, per violation (Clean Air Act & Montreal Protocol)

    Clean Air Act civil penalties are assessed per day for each violation, and the maximum amount is adjusted for inflation each year, so the total can grow very quickly.

    Source: EPA – Section 608 Test Topics

  14. B. All stationary air-conditioning and refrigeration equipment containing CFCs, HCFCs or non-exempt substitutes (MVACs are covered under Section 609) (Section 608 regulations)

    Section 608 covers stationary refrigeration and AC appliances with CFC, HCFC or non-exempt substitute refrigerants. MVACs are handled under the Section 609 program.

    Source: EPA – Section 608 Test Topics

  15. B. 1.5% (The three Rs: recover, recycle, reclaim)

    40 CFR 82.164 requires reclaimers to release no more than 1.5 percent of the refrigerant during reclamation.

    Source: EPA – Refrigerant Reclamation Requirements

  16. A. High-pressure, high-temperature vapor (Refrigeration cycle & gauges)

    The compressor raises refrigerant pressure and temperature, discharging a high-pressure, high-temperature (superheated) vapor to the condenser.

    Source: EPA – Section 608 Test Topics

  17. A. Speeds recovery (Recovery & dehydration)

    Long, narrow hoses add flow restriction. Shorter, larger-diameter hoses reduce restriction and speed up recovery.

    Source: EPA – Section 608 Test Topics

  18. C. B2L (A2L, A3 & low-GWP refrigerants)

    Ammonia is higher toxicity (B) and lower flammability (2L), so it is B2L.

    Source: EPA – Refrigerant Safety (ASHRAE Standard 34 classes)

  19. B. HCFC (Ozone depletion & environmental impact)

    R-22 (HCFC-22) is a hydrochlorofluorocarbon: it contains hydrogen, chlorine, fluorine and carbon, so it still depletes ozone but much less than CFCs.

    Source: EPA – Section 608 Test Topics

  20. B. Must never be refilled (Shipping & cylinders)

    Disposable cylinders must never be refilled. Use only DOT-approved refillable recovery cylinders for recovered refrigerant.

    Source: EPA – Section 608 Test Topics

  21. C. Many substitute refrigerants are not compatible with lubricants used with CFCs and HCFCs (Substitute refrigerants & oils)

    Substitute refrigerants are incompatible with many lubricants used with CFC and HCFC refrigerants (and vice versa), which affects oil return and system reliability.

    Source: EPA – Section 608 Test Topics

  22. D. Safety glasses/goggles and gloves (Safety)

    EPA lists gloves and goggles as PPE for refrigerant handling, and a self-contained breathing apparatus (SCBA) in extreme cases such as a large release.

    Source: EPA – Section 608 Test Topics

  23. C. Any person, including technicians, who violates the rules (Clean Air Act & Montreal Protocol)

    The Clean Air Act lets EPA bring civil and criminal enforcement against any person who violates the refrigerant rules, including technicians, owners and sellers. Penalties are per day, per violation, and EPA can also revoke a technician's certification (40 CFR 82.161(a)(3)).

    Source: Clean Air Act §113 (42 U.S.C. 7413)

  24. A. Type II (Section 608 regulations)

    Type II covers medium-, high- and very high-pressure appliances other than small appliances, MVACs and MVAC-like appliances.

    Source: EPA – Section 608 Technician Certification Requirements

  25. D. A reclaimer certified with EPA that meets the AHRI 700 specifications (The three Rs: recover, recycle, reclaim)

    40 CFR 82.164: persons reclaiming used refrigerant for sale to a new owner must certify to EPA and reclaim to AHRI 700 specifications, verifying each batch.

    Source: EPA – Refrigerant Reclamation Requirements