Skip to content
TradeCert Prep
Free practice · Type III

EPA 608 Type 3 Practice Test

Quick answer: The EPA 608 Type III section covers low-pressure appliances, including centrifugal chillers. The certification test combines 25 Type III questions with 25 Core questions and requires 70% in each section. This section has 78 published free practice questions with answer explanations and cited sources.

Last reviewed: November 24, 2026

10 published questionsFeedback appears after each answer
Type III · Leak repair requirementsQuestion 1 of 10

A low-pressure centrifugal chiller cooling an office building with 1,000 lb of R-123 falls under which leak-rate trigger?

Answer choices for question 1

Keyboard: A–D to choose · Enter to check

Type III · Recovery & recharging techniquesQuestion 2 of 10

Centrifugal chillers are typically charged through the:

Answer choices for question 2

Keyboard: A–D to choose · Enter to check

Type III · Purge units & refrigerationQuestion 3 of 10

A purge unit vents mostly refrigerant instead of air. This means:

Answer choices for question 3

Keyboard: A–D to choose · Enter to check

Type III · Type III safetyQuestion 4 of 10

When heating a low-pressure system to raise pressure for leak testing or repair, the technician must:

Answer choices for question 4

Keyboard: A–D to choose · Enter to check

Type III · Evacuation requirementsQuestion 5 of 10

The 25 mm Hg absolute requirement for low-pressure appliances applies when:

Answer choices for question 5

Keyboard: A–D to choose · Enter to check

Type III · Leak detectionQuestion 6 of 10

Low-pressure chillers (e.g., R-123) operate with the evaporator below atmospheric pressure. Because of this, leaks usually cause:

Answer choices for question 6

Keyboard: A–D to choose · Enter to check

Type III · Leak repair requirementsQuestion 7 of 10

A retrofit or retirement plan for a leaking appliance must be kept:

Answer choices for question 7

Keyboard: A–D to choose · Enter to check

Type III · Recovery & recharging techniquesQuestion 8 of 10

A technician recovering R-11 or R-123 from a chiller notices recovery is slowing. Which helps?

Answer choices for question 8

Keyboard: A–D to choose · Enter to check

Type III · Purge units & refrigerationQuestion 9 of 10

Moisture and air entering a low-pressure system can cause:

Answer choices for question 9

Keyboard: A–D to choose · Enter to check

Type III · Type III safetyQuestion 10 of 10

Which PPE is recommended when sampling oil or refrigerant from a chiller?

Answer choices for question 10

Keyboard: A–D to choose · Enter to check

78 published questions in this section. Free Type III EPA 608 practice with instant feedback, explanations, and source links.

Ready for a full-length run?

Take a free timed mock for Type III or the full Universal: real section length and pass mark, instant score, no signup.

What's on the EPA 608 Type III test

Each set above is balanced across these topics. The counts show how many sourced practice questions we have for each topic, not the official exam weighting.

Type III topics in our practice bank
TopicPractice questions
Leak detection13
Leak repair requirements10
Recovery & recharging techniques17
Evacuation requirements12
Purge units & refrigeration16
Type III safety10

Key numbers for Type III

Low-pressure systems

  • Evacuate low-pressure appliances to 25 mm Hg absolute. (40 CFR 82.156(a), Table 1)
  • Pressurize for leak testing to no more than 10 psig; the rupture disc relieves at 15 psig. (EPA – Section 608)
  • Change oil only when the system is at 5 psig or less. Heat the oil to about 130°F to drive off dissolved refrigerant. (EPA – Section 608)

More in the full EPA 608 cheat sheet.

Keep going

Frequently asked questions

What does a Type 3 EPA certification mean?

Type III certifies you to service low-pressure appliances, mainly centrifugal chillers that run below atmospheric pressure on the low side. The test is 25 Core plus 25 Type III questions.

Why do people find Type III hard?

Low-pressure chillers are specialized commercial equipment, so purge units, rupture discs, water-side leak testing and vapor-before-liquid charging are new material for techs who don't work on them.