Quick answer: Below are 40 EPA 608 practice questions with answers, 10 each from Core, Type I, Type II, and Type III. Each answer stays hidden until you open it and comes with an explanation and the rule it is based on. These are practice questions written from EPA and eCFR sources, not the confidential exam forms. The set changes each quarter.
By the TradeCert Prep editorial team · Last reviewed: November 26, 2026 · How we research and check our content
How to use these questions
Read the question, pick your answer before opening it, then read the explanation even when you were right. Reading answers feels productive, but recall is what the test measures. When you can explain why each wrong option is wrong, move on to a timed practice test. Our full bank has 393 questions.
EPA 608 Core questions and answers
Where in the atmosphere is the protective ozone layer that CFCs damage?
Show answer
Answer: B. Stratosphere
Why: The ozone layer that absorbs most UVB radiation is in the stratosphere. CFCs are stable in the lower atmosphere (troposphere) and drift up to the stratosphere, where UV light breaks them apart. EPA – Basic Ozone Layer Science
Refillable recovery cylinders should be filled to no more than about what percent of capacity by weight?
Show answer
Answer: D. 80%
Why: Do not fill recovery cylinders beyond about 80 percent of capacity. The remaining space allows liquid to expand with temperature without hydrostatic rupture. EPA – Section 608 Test Topics
A refrigerant cylinder should never be heated with:
Show answer
Answer: C. An open flame or torch
Why: Never use an open flame or direct torch heat on a cylinder; it can over-pressurize and rupture the cylinder or decompose the refrigerant. EPA – Section 608 Test Topics
Which of these is exempt from the Section 608 venting prohibition?
Show answer
Answer: C. Isobutane (R-600a) in household refrigerators
Why: 40 CFR 82.154(a)(1) exempts specific substitutes in specific end uses, including R-600a in household refrigerators and freezers. HFC and HFC/HFO refrigerants in AC equipment are not exempt. 40 CFR 82.154 – Prohibitions
According to 40 CFR 82.152, R-134a and R-12 systems are classified as:
Show answer
Answer: B. Medium-pressure appliances
Why: Medium-pressure appliances use refrigerants with a saturation pressure between 45 and 170 psia at 104°F; examples include R-114, R-124, R-12, R-134a and R-500. They are serviced under Type II. 40 CFR 82.152 – Definitions
On a standard manifold gauge set, the low-side (compound) gauge is colored:
Show answer
Answer: B. Blue
Why: By convention the low-side compound gauge and hose are blue, the high-side gauge and hose are red, and the center utility/charging hose is yellow. EPA – Section 608 Test Topics
Which practice improves the speed and quality of dehydration evacuation?
Show answer
Answer: A. Using short, large-diameter hoses and removing Schrader cores
Why: Shorter, larger hoses and core removal reduce restriction. Fresh vacuum pump oil also helps the pump reach a deep vacuum. EPA – Section 608 Test Topics
Which refrigerant was the likely substitute for CFC-12 (R-12) in small appliances?
Show answer
Answer: A. HFC-134a
Why: EPA's Type I test topics name HFC-134a (R-134a) as the likely substitute for CFC-12 (R-12). EPA – Section 608 Test Topics
As of January 1, 2020, what changed for HCFC-22 (R-22) in the United States?
Show answer
Answer: A. Production and import of R-22 ended
Why: Under the HCFC phaseout schedule, production and import of HCFC-22 ended in 2020. Existing systems can still be serviced with recovered, recycled or reclaimed R-22. EPA – Phaseout of Class II Ozone-Depleting Substances
A technician removes refrigerant from a customer's unit, cleans it through a filter-drier on site and returns it to the same unit. This is:
Show answer
Answer: B. Recycling
Why: Cleaning refrigerant for reuse (oil separation, filter-driers) without bringing it to AHRI 700 and verifying by analysis is recycling. EPA – Section 608 Test Topics
More Core practice · Printable Core questions with answer key
EPA 608 Type I questions and answers
Under Section 608, a 'small appliance' is one that is fully manufactured, charged and hermetically sealed in a factory with:
Show answer
Answer: C. 5 pounds or less of refrigerant
Why: 40 CFR 82.152 defines a small appliance as fully manufactured, charged and hermetically sealed in a factory with five pounds or less of refrigerant. 40 CFR 82.152 – Definitions
Which refrigerant is the common HFC replacement for R-12 in household refrigerators?
Show answer
Answer: A. R-134a
Why: HFC-134a was the likely substitute for CFC-12 in small appliances, according to EPA's Type I test topics. EPA – Section 608 Test Topics
Before cutting into the tubing of a refrigerator, the technician must:
Show answer
Answer: A. Recover the refrigerant
Why: Cutting lines without recovery is knowing venting. Recover first, then cut. EPA – Prohibition on Venting Refrigerants
Using recovery equipment manufactured BEFORE November 15, 1993, on a small appliance, you must recover:
Show answer
Answer: B. 80% of the refrigerant regardless of compressor condition
Why: With pre-11/15/1993 recovery equipment, the requirement is 80% recovery whether the compressor works or not (or evacuation to 4 inches Hg vacuum). EPA – Stationary Refrigeration Service Practice Requirements
Chilling the recovery container during recovery from a small appliance will:
Show answer
Answer: C. Lower the container pressure and speed recovery
Why: Lowering the recovery vessel's temperature lowers its pressure, increasing the pressure difference and speeding refrigerant transfer. EPA – Section 608 Test Topics
Refrigerant exposed to an open flame or hot surface can decompose into toxic products. Which is one of them?
Show answer
Answer: B. Phosgene
Why: EPA's Type I safety topic covers decomposition products of refrigerants at high temperatures, which can include phosgene, hydrochloric acid and hydrofluoric acid. EPA – Section 608 Test Topics
Does a person need Section 608 certification to recover refrigerant from a small appliance being prepared for disposal?
Show answer
Answer: D. No, but they must use recovery equipment that meets EPA performance standards
Why: EPA says people recovering refrigerant from small appliances for disposal don't have to be certified, but the recovery equipment must meet the same performance standards and venting is still prohibited. EPA – Stationary Refrigeration Safe Disposal Requirements
The refrigerant in a small appliance should be identified before recovery mainly to:
Show answer
Answer: C. Avoid mixing different refrigerants in the recovery container
Why: Identifying the refrigerant (nameplate, PT relationship) helps avoid mixing refrigerants, which can make the recovered refrigerant impossible to reclaim. EPA – Section 608 Test Topics
A refillable recovery cylinder used for small-appliance recovery should be inspected for:
Show answer
Answer: C. Its hydrostatic test date, damage, rust, and a working valve
Why: Check DOT recovery cylinders for a current hydrostatic test date, physical damage, rust and valve condition, and never fill beyond 80% capacity. EPA – Section 608 Test Topics
How long must the final processor keep signed statements or contracts for disposed small appliances?
Show answer
Answer: B. 3 years
Why: 40 CFR 82.155(c): the final processor must keep copies of signed statements or contracts on site for three years. 40 CFR 82.155 – Safe disposal of appliances
More Type I practice · Printable Type I questions with answer key
EPA 608 Type II questions and answers
Under the Section 608 leak repair rule (40 CFR 82.157), leak repair requirements for appliances using an ozone-depleting refrigerant such as R-22 apply when the full charge is:
Show answer
Answer: B. 50 pounds or more
Why: 40 CFR 82.157(a): since April 10, 2020, the Section 608 leak repair requirements apply only to appliances with a full charge of 50 or more pounds of a class I or class II (ozone-depleting) refrigerant. Note: since January 1, 2026, a separate HFC rule (40 CFR 84.106, AIM Act) applies similar leak repair rules to appliances with 15 lb or more of an HFC or a substitute with GWP above 53, except residential and light commercial AC and heat pumps. 40 CFR 82.157 – Appliance maintenance and leak repair
After reaching the required recovery vacuum, a technician should wait a few minutes to see if the pressure rises. A rise indicates:
Show answer
Answer: B. There is still liquid refrigerant in the system or in the oil
Why: EPA: wait a few minutes after reaching the required vacuum. If pressure rises, liquid refrigerant remains in the system or the oil, and recovery should continue. EPA – Section 608 Test Topics
Which component lowers refrigerant pressure before the evaporator?
Show answer
Answer: D. Metering device (e.g., TXV, capillary tube, piston)
Why: The metering device (TXV, fixed orifice or capillary tube) creates the pressure drop from the high side to the low side. EPA – Section 608 Test Topics
A standing pressure test with nitrogen detects leaks when:
Show answer
Answer: B. Pressure drops over time (temperature held steady)
Why: After pressurizing with nitrogen, a pressure drop over time at a constant temperature indicates a leak. 40 CFR 82.157 – Appliance maintenance and leak repair
You find red-marked service ports and line-set sections on a new heat pump. What do they indicate?
Show answer
Answer: C. The system contains a flammable (A2L) refrigerant
Why: SNAP use conditions require red marking at service locations of AC equipment using A2L refrigerants such as R-32 and R-454B. EPA SNAP Rule 23, 86 FR 24444 (May 6, 2021)
Which of the following is a MAJOR repair under Section 608?
Show answer
Answer: A. Removing the compressor, condenser, evaporator or auxiliary heat exchange coil
Why: 40 CFR 82.152: major maintenance, service or repair involves removing the compressor, condenser, evaporator or auxiliary heat exchange coil, or uncovering an opening of more than 4 square inches of flow area for more than 15 minutes. 40 CFR 82.152 – Definitions
What is the leak-rate trigger for comfort cooling appliances?
Show answer
Answer: B. 10%
Why: Comfort cooling has a 10% trigger leak rate. Under 40 CFR 82.157 this applies to appliances with 50 lb or more of an ozone-depleting refrigerant; since January 1, 2026, 40 CFR 84.106 applies the same 10% rate to comfort cooling appliances with 15 lb or more of an HFC or other substitute with GWP above 53 (residential and light commercial AC and heat pumps are excluded). EPA – Stationary Refrigeration Leak Repair Requirements
Why is a recovery cylinder sometimes placed in ice water during recovery?
Show answer
Answer: B. To lower its pressure and speed recovery
Why: Cooling the cylinder lowers its pressure, which increases the pressure difference and speeds refrigerant transfer. EPA – Section 608 Test Topics
Why should you not open the system or add refrigerant before identifying the refrigerant in it?
Show answer
Answer: B. Mixing refrigerants causes unpredictable pressures and can make recovered refrigerant unreclaimable
Why: Mixed refrigerants have unpredictable PT behavior and may be impossible to reclaim. Always identify the refrigerant first. EPA – Section 608 Test Topics
If a tracer gas is needed so an electronic detector can sense a leak, what is acceptable according to EPA test topics?
Show answer
Answer: D. Nitrogen with a trace quantity of HCFC-22
Why: EPA's Type II topics rank leak-test gases: nitrogen alone is best, and nitrogen with only a trace of HCFC-22 (so an electronic detector can sense it) is better than pressurizing with pure refrigerant. EPA – Section 608 Test Topics
More Type II practice · Printable Type II questions with answer key
EPA 608 Type III questions and answers
When heating a low-pressure system to raise pressure for leak testing or repair, the technician must:
Show answer
Answer: B. Use controlled heat (such as hot water or Prevac) and not exceed the rupture disc rating
Why: Controlled hot water or a Prevac device is used. Pressure must stay well below the rupture disc rating. EPA – Section 608 Test Topics
Low-pressure appliances must be evacuated to what level using recovery equipment made BEFORE Nov 15, 1993?
Show answer
Answer: C. 25 mm Hg absolute
Why: EPA's table lists 25 mm Hg absolute for low-pressure appliances with both pre- and post-1993 recovery equipment. EPA – Stationary Refrigeration Service Practice Requirements
Heating the oil to 130°F before draining it from a low-pressure chiller helps because:
Show answer
Answer: B. Warm oil holds less dissolved refrigerant, so the refrigerant boils out before the oil is drained
Why: Warm oil releases dissolved refrigerant, so less refrigerant leaves with the drained oil. EPA – Section 608 Test Topics
A sign of leakage into a low-pressure system is:
Show answer
Answer: B. Excessive purging (the purge unit running often)
Why: EPA's Type III topics list excessive purging as a sign of leakage. The purge unit has to keep removing air that is leaking in. EPA – Section 608 Test Topics
Which low-GWP refrigerant does EPA list (A1) as a substitute in centrifugal chillers, including low-pressure machines?
Show answer
Answer: D. R-1233zd(E)
Why: EPA's SNAP list for centrifugal chillers includes R-1233zd(E), an A1 low-pressure HCFO refrigerant with a near-zero ODP (about 0.0003) and a GWP under 10, used in new low-pressure chillers as an R-123 alternative. EPA SNAP – Substitutes in centrifugal chillers
Purged refrigerant destroyed at a verified destruction efficiency of at least ___ may be excluded from leak-rate calculations.
Show answer
Answer: D. 98%
Why: 82.157(k): purged refrigerant destroyed at 98% or greater verifiable efficiency is not counted toward the leak rate. 40 CFR 82.157 – Appliance maintenance and leak repair
Under ASHRAE Standard 15, an equipment room with an R-123 chiller requires:
Show answer
Answer: D. A refrigerant sensor/monitor (in addition to oxygen deprivation protection)
Why: EPA's Type III topics: under ASHRAE 15, an equipment room refrigerant sensor is needed for R-123, and oxygen deprivation sensors are needed for all refrigerants. EPA – Section 608 Test Topics
If leaks make it impossible to reach 25 mm Hg absolute, the technician must evacuate leaking components to the lowest level achievable without substantially contaminating the refrigerant, but not higher than:
Show answer
Answer: B. 0 psig
Why: 40 CFR 82.156(a)(2)(iii): evacuate leaking components to the lowest attainable level, which may not exceed 0 psig. EPA – Stationary Refrigeration Service Practice Requirements
Liquid refrigerant in a low-pressure chiller is typically removed from:
Show answer
Answer: A. The bottom of the evaporator (liquid drain/valve)
Why: Liquid collects at the bottom of the evaporator, so liquid recovery connections are made there. EPA – Section 608 Test Topics
A low-pressure chiller's purge unit runs much more than normal. The technician should first suspect:
Show answer
Answer: D. An air leak into the system
Why: Frequent purging means non-condensables are entering, which usually indicates a leak somewhere in the vacuum side of the system. EPA – Section 608 Test Topics
More Type III practice · Printable Type III questions with answer key
Now try them under the clock
A timed 25-question section with the real pass mark is the closest thing to test day.
Frequently asked questions
Are these the real EPA 608 test questions?
No. Certifying organizations keep their test forms secure. These are original practice questions written from EPA and eCFR sources, covering the same rules and topics the real test asks about.
Is there an EPA 608 questions and answers PDF?
Yes. Each section has a printable version with an answer key: Core, Type I, Type II and Type III. Use your browser's Print or Save as PDF option.