Quick answer: R-410A is an HFC blend of R-32 and R-125 (50/50) the main refrigerant in new U.S. home AC and heat pumps from 2010, when R-22 could no longer be used in new equipment, until the 2025 GWP limit. It is A1 (non-flammable), with zero ozone depletion but a GWP of 2,088. It is not banned: existing systems can still be serviced, but new systems installed from 2025 must use a refrigerant with GWP of 700 or less, such as R-454B or R-32.
By the TradeCert Prep editorial team · Last reviewed: November 26, 2026 · How we research and check our content
| Type | HFC blend — R-32/R-125, 50/50 by mass |
|---|---|
| ASHRAE safety class | A1 |
| Global warming potential (100-year) | 2,088 (EPA) |
| Ozone depletion potential | 0 (EPA) |
| Typical equipment | Residential split AC and heat pumps installed from about 2010 to 2024 |
| Regulatory status | New residential and light-commercial AC systems are limited to GWP 700 from January 1, 2025 (systems whose components were all made before then are exempt); servicing existing equipment is not restricted. |
R-410A pressures at common temperatures
| Temperature | Liquid (bubble) | Vapor (dew) |
|---|---|---|
| 65°F | 185.8 | 185.1 |
| 75°F | 218.7 | 217.9 |
| 85°F | 255.4 | 254.6 |
| 95°F | 296.4 | 295.5 |
From our P-T dataset. A system that has been off long enough to reach ambient temperature should read close to these values (a "standing pressure"); see the full R-410A P-T chart for every temperature.
Is R-410A being phased out?
Two separate EPA programs affect R-410A, and neither bans servicing existing systems:
- The HFC phasedown limits how much HFC can be produced or imported, as a share of a baseline: 90% (2020–2023), 60% (2024–2028), 30% (2029–2033), 20% (2034–2035) and 15% from 2036 (EPA). EPA notes that HFC availability may lessen over time.
- Technology Transitions sets a 700 GWP limit for new residential and light-commercial AC and heat pump systems from January 1, 2025, with no installation deadline for systems whose components were all made before that date. Variable refrigerant flow (VRF) systems follow from January 1, 2027 (EPA).
EPA states that "components used to repair existing systems are not subject to these restrictions," and that consumers can keep using their equipment to the end of its useful life.
What replaces R-410A?
New equipment mostly uses R-454B (GWP 465) or R-32 (GWP 675). Both are A2L, lower flammability, and EPA SNAP lists them for new equipment only, not as retrofits for R-410A systems (EPA SNAP). There is no drop-in replacement: a system is designed for one refrigerant. Compare pressures in R-410A vs R-454B vs R-32.
Servicing R-410A systems
- Oil: HFC systems generally use ester (POE) lubricants, because HFCs don't mix well with traditional mineral oil (EPA test topics).
- It's a blend: blend components can leak at different rates (fractionation), so follow the manufacturer's charging instructions; blends are normally charged as liquid from the cylinder.
- Venting is illegal. Recover R-410A like any other refrigerant; see refrigerant recovery.
- Buying it requires EPA 608 certification (EPA sales restriction).
On the EPA 608 exam
Refrigerant types, oils and replacements appear in the Core section. Test yourself on real practice questions.
Test yourself: 6 EPA 608 practice questions
Need your EPA 608 to buy R-410A?
The certification test is open to anyone. Find out if you'd pass today with a free timed practice test.
Frequently asked questions
Is R-410A refrigerant discontinued?
No. R-410A is still produced under declining HFC allowances and can be used to service existing equipment. What changed is that new residential and light-commercial AC systems installed from January 1, 2025 must use a refrigerant with GWP of 700 or less, unless all their components were made before 2025.
Can anybody buy R-410A refrigerant?
No. EPA's sales restriction covers refrigerant in cylinders and drums; buyers must be Section 608-certified technicians or employers who give the wholesaler written proof that they employ one.
Can I keep using my R-410A system?
Yes. EPA says consumers can keep using existing equipment until the end of its useful life, and components used to repair existing systems are not subject to the new restrictions.
Sources
- EPA — Technology Transitions GWP Reference Table (updated April 2, 2026)
- EPA — Technology Transitions HFC Restrictions by Sector (updated August 28, 2026)
- EPA — Frequent Questions on the Phasedown of HFCs
- EPA SNAP — Substitutes in Residential and Light Commercial AC and Heat Pumps (updated March 19, 2026)
- EPA — Refrigerant Sales Restriction (updated March 23, 2026)
- EPA — Section 608 Test Topics (updated November 24, 2026)
- TradeCert Prep P-T data (computed with CoolProp 8.1.0; see methodology)