EPA 608 Type 1 Practice Test

Quick answer: The EPA 608 Type I section covers small appliances factory-sealed with 5 pounds or less of refrigerant, including recovery and safety. The closed-book proctored test has 25 type questions plus 25 Core questions; its pass mark is 70% per section, while mail-in Type I requires 84%. This section has 66 published free practice questions with explanations and sources.

Last reviewed: November 24, 2026

10 published questionsFeedback appears after each answer
Type I · Type I safetyQuestion 1 of 10

If a small appliance's refrigerant has been contaminated by a compressor burnout, the recovered refrigerant:

Answer choices for question 1

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery techniquesQuestion 2 of 10

When you install a piercing-type access valve on a small appliance, what is good practice?

Answer choices for question 2

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery requirementsQuestion 3 of 10

Using recovery equipment manufactured AFTER November 15, 1993, on a small appliance with an OPERATING compressor, you must recover:

Answer choices for question 3

Keyboard: A–D to choose · Enter to check

Type I · Type I safetyQuestion 4 of 10

A small appliance that previously had a compressor burnout may contain:

Answer choices for question 4

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery techniquesQuestion 5 of 10

System-dependent (passive) recovery on a small appliance with a WORKING compressor requires you to:

Answer choices for question 5

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery requirementsQuestion 6 of 10

Under Section 608, a 'small appliance' is one that is fully manufactured, charged and hermetically sealed in a factory with:

Answer choices for question 6

Keyboard: A–D to choose · Enter to check

Type I · Type I safetyQuestion 7 of 10

Which ASHRAE safety class applies to isobutane (R-600a) in household refrigerators?

Answer choices for question 7

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery techniquesQuestion 8 of 10

A small appliance's sealed system has been opened and repaired. Before recharging, you should:

Answer choices for question 8

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery requirementsQuestion 9 of 10

What is the passing score for a mail-in format Type I test?

Answer choices for question 9

Keyboard: A–D to choose · Enter to check

Type I · Type I safetyQuestion 10 of 10

When working with a flammable refrigerant such as R-290 or R-600a, technicians should:

Answer choices for question 10

Keyboard: A–D to choose · Enter to check

66 published questions in this section. Free Type I EPA 608 practice with instant feedback, explanations, and source links.

Ready for a full-length run?

Take a free timed mock for Type I or the full Universal: real section length and pass mark, instant score, no signup.

What's on the EPA 608 Type I test

Each set above is balanced across these topics. The counts show how many sourced practice questions we have for each topic, not the official exam weighting.

Type I topics in our practice bank
TopicPractice questions
Small appliance recovery requirements25
Small appliance recovery techniques27
Type I safety14

Key numbers for Type I

Small appliances (Type I)

  • Recovery equipment made before Nov. 15, 1993: recover 80% of the refrigerant. Equipment made on or after Nov. 15, 1993: recover 90% when the appliance compressor works, or 80% when it does not. Or evacuate the appliance to 4 in Hg vacuum. (40 CFR 82.156(b))
  • System-dependent recovery equipment may not be used on appliances with a full charge of more than 15 lb unless it is permanently attached as a pump-out unit. (40 CFR 82.156(e))

More in the full EPA 608 cheat sheet.

Keep going

Frequently asked questions

What is an EPA Type 1 certification?

Type I certifies you to service small appliances: factory-sealed equipment with 5 lb or less of refrigerant, such as refrigerators, freezers, window AC units and dehumidifiers. The test is 25 Core questions plus 25 Type I questions.

Can I take the EPA Type 1 test open-book?

Yes. Type I may be offered as an open-book test, but it requires 84% (21 of 25) instead of 70%, and an open-book result cannot count toward Universal.

What is EPA Type 1 and 2?

A tech certified in Type I and Type II has passed Core plus both type sections. That covers small appliances and high-pressure equipment, but not low-pressure chillers (Type III).