Skip to content
TradeCert Prep
Free practice · Core

Refrigeration cycle & gauges: Core practice

15 published questions in this topic. Free Refrigeration cycle & gauges practice for EPA 608 Core, with instant feedback, explanations and source links.

10 published questionsFeedback appears after each answer
Core · Refrigeration cycle & gaugesQuestion 1 of 10

On a standard manifold gauge set, the high-side gauge is colored:

Answer choices for question 1

Keyboard: A–D to choose · Enter to check

Core · Refrigeration cycle & gaugesQuestion 2 of 10

The suction line between the evaporator and compressor normally carries:

Answer choices for question 2

Keyboard: A–D to choose · Enter to check

Core · Refrigeration cycle & gaugesQuestion 3 of 10

In the condenser, refrigerant:

Answer choices for question 3

Keyboard: A–D to choose · Enter to check

Core · Refrigeration cycle & gaugesQuestion 4 of 10

A saturated refrigerant (liquid and vapor present together) in a closed container has a pressure that depends on:

Answer choices for question 4

Keyboard: A–D to choose · Enter to check

Core · Refrigeration cycle & gaugesQuestion 5 of 10

Superheat is:

Answer choices for question 5

Keyboard: A–D to choose · Enter to check

Core · Refrigeration cycle & gaugesQuestion 6 of 10

Subcooling is:

Answer choices for question 6

Keyboard: A–D to choose · Enter to check

Core · Refrigeration cycle & gaugesQuestion 7 of 10

In a vapor-compression system, refrigerant leaves the compressor as a:

Answer choices for question 7

Keyboard: A–D to choose · Enter to check

Core · Refrigeration cycle & gaugesQuestion 8 of 10

After passing through the metering device, refrigerant enters the evaporator as a:

Answer choices for question 8

Keyboard: A–D to choose · Enter to check

Core · Refrigeration cycle & gaugesQuestion 9 of 10

Refrigerant entering the metering device is normally a:

Answer choices for question 9

Keyboard: A–D to choose · Enter to check

Core · Refrigeration cycle & gaugesQuestion 10 of 10

A compound gauge can read:

Answer choices for question 10

Keyboard: A–D to choose · Enter to check

Ready for a full-length run?

Take a free timed mock for Core or the full Universal: real section length and pass mark, instant score, no signup.

About this topic

The refrigeration cycle and the role of service gauges. This page draws 10 questions from the 15 sourced Core questions we have on refrigeration cycle & gauges; each answer explains why and links to the rule it tests.

On the real test: Every Core section on the real exam has 25 questions drawn across all Core topics, and you need 18 of 25 (70%) on the closed-book test. Our bank has 15 practice questions on this topic. Expect questions like: “Refrigerant entering the metering device is normally a:” and “After passing through the metering device, refrigerant enters the evaporator as a:”

Key facts to remember

  • To convert a gauge reading in psig to psia, you Add 14.7 (source)
  • A gauge reading of 0 psig at sea level equals about 14.7 psia (source)
  • Standard atmospheric pressure expressed in inches of mercury is about 29.9 in Hg (source)

Keep studying