This lesson covers finding leaks in high-pressure systems: the signs of a leak, leak detection methods, and safe leak testing.
Key numbers
- If a tracer gas is needed so an electronic detector can sense a leak, what is acceptable according to EPA test
- Nitrogen with a trace quantity of HCFC-22
- Source
Key concepts
Signs of a leak
EPA's Type II topics list excessive superheat as a sign of leakage. A low charge starves the evaporator, so vapor leaving it is heated more than normal.
Source: EPA – Section 608 Test Topics.
Oil traces
Oil travels with refrigerant, so oil traces at joints and fittings are a classic sign of a leak, as listed in EPA's Type II topics.
Source: EPA – Section 608 Test Topics.
Leak test before charging
EPA's Type II topics include the need to leak test before charging or recharging equipment.
Source: EPA – Section 608 Test Topics.
What to know
- EPA's order of preference: nitrogen alone is best. Nitrogen with a trace quantity of R-22 is better than pure refrigerant.
- Soap bubbles, electronic or ultrasonic leak detectors, fluorescent dye with UV light and similar tools are listed EPA verification methods.
- Soap bubbles, electronic/ultrasonic detectors, dye with UV light, pressure or vacuum tests and infrared detectors are leak detection methods. Thermostat setpoint is not.
- In a standing pressure test, the system is pressurized with nitrogen; a pressure drop over time at a steady temperature indicates a leak.
- If pressure rises after isolating the pump, either a leak is letting air in or moisture/refrigerant is still boiling off.
- Leak test a system before charging it, so refrigerant isn't lost through leaks afterward. Charging a leaking system wastes refrigerant and releases it to the environment.
- Electronic detectors need time to sense trace gas, so probe slowly and close to joints. Because refrigerant is heavier than air, check below fittings too.
- 40 CFR 82.152: follow-up verification tests check repairs after a successful initial verification test and after the appliance returns to normal operating characteristics.
Source: EPA – Section 608 Test Topics, 40 CFR 82.157 – Appliance maintenance and leak repair, 40 CFR 82.152 – Definitions.
Scenario
A technician finishes repairing the leaks on an appliance over its trigger rate. The initial verification test is done right after the repairs, before refrigerant is added back, to confirm the leaks were repaired.
Source: 40 CFR 82.157 – Appliance maintenance and leak repair.