Printable EPA 608 Type I Practice Test with Answer Key
Answer each question, then use the key at the end to check your work. This is an independent practice set, not an official certification test.
Last reviewed: November 24, 2026
Practice questions
Large amounts of refrigerant released in a small, enclosed room can:
- Displace oxygen and cause suffocation
- Be harmless because refrigerants are non-toxic
- Increase oxygen
- Cool the room safely
When recovering from a small appliance with a working compressor using a passive device, which access point is typically used?
- Only the suction line with the unit off
- None; passive recovery needs no access
- The high side, with the appliance compressor running
- The evaporator drain
Under Section 608, a 'small appliance' is one that is fully manufactured, charged and hermetically sealed in a factory with:
- Any amount of refrigerant
- 50 pounds or less of refrigerant
- 5 pounds or less of refrigerant
- 15 pounds or less of refrigerant
An acrid or sharp odor while repairing a refrigerator that has burned out may indicate:
- Too much oil
- Normal operation
- A good compressor
- Refrigerant decomposition or acid in the system
System-dependent recovery devices capture refrigerant in a non-pressurized container. Before connecting it, the container should be:
- Filled with water
- Heated
- Filled with nitrogen
- Evacuated
Does a person need Section 608 certification to recover refrigerant from a small appliance being prepared for disposal?
- Yes, Universal is required
- No, and they can vent it
- Yes, Type I is required
- No, but they must use recovery equipment that meets EPA performance standards
Pressurizing a refrigerator with oxygen to find a leak is dangerous because:
- Oxygen damages copper
- Oxygen and compressor oil can explode under pressure
- Oxygen is heavier than air
- Oxygen is too cold
Self-contained (active) recovery equipment used on small appliances:
- Uses its own compressor and can recover whether or not the appliance compressor works
- Requires the appliance compressor to run
- Never needs certification
- Is prohibited on small appliances
Recovery equipment used on small appliances must be certified to recover what percentages on the test stand?
- 90% with compressor running and 80% with it not running
- 100% in all cases
- 95% and 90%
- 80% and 70%
When working with a flammable refrigerant such as R-290 or R-600a, technicians should:
- Use a torch to find leaks
- Eliminate ignition sources and ventilate the area
- Vent indoors
- Store cylinders near the furnace
When recovering refrigerant from a small appliance with an inoperative compressor using a passive method, a vacuum pump may be used:
- Only if it discharges into a non-pressurized recovery container
- Only with oxygen
- Never
- To vent refrigerant to the air
A vending machine with a seized compressor is being repaired with a 2010 recovery machine. The minimum recovery is:
- 100%
- 70%
- 90%
- 80% (or 4 inches Hg vacuum)
If a small appliance's refrigerant has been contaminated by a compressor burnout, the recovered refrigerant:
- Should be kept separate and sent for reclamation or destruction
- Can be sold to another customer
- Should be vented
- Should be added to a clean system
Recovery from a small appliance is complete when:
- The gauges read 0 psig for one second
- The cabinet is warm
- The compressor stops
- The required recovery percentage is reached, or the appliance is evacuated to 4 inches Hg vacuum
Can a mail-in format Type I test be used toward Universal certification?
- Only if scored above 90%
- Yes
- Only with EPA approval
- No
Many new household refrigerators use isobutane (R-600a). What added hazard must you control when servicing one?
- Extremely high pressure
- Flammability: keep ignition sources away
- High toxicity
- Ozone depletion
To identify the refrigerant in a small appliance and detect non-condensables, you can compare:
- The age of the appliance
- The appliance's color and size
- The system's standing pressure with its temperature on a PT chart
- The voltage and amperage
Instead of meeting the percentage recovery requirements, a technician may evacuate a small appliance to:
- 4 inches of mercury vacuum
- 10 inches of mercury vacuum
- 0 psig
- 500 microns
A refillable recovery cylinder used for small-appliance recovery should be inspected for:
- Its brand
- Its weight when empty only
- Its hydrostatic test date, damage, rust, and a working valve
- Paint color only
Which recovery cylinder is acceptable for self-contained recovery from a small appliance?
- An oxygen cylinder
- A plastic recovery bag
- A disposable 30 lb cylinder
- A DOT-approved refillable recovery cylinder
Is a sticker on an appliance acceptable proof that refrigerant was recovered before disposal?
- Only for vending machines
- Only for refrigerators
- Yes, always
- No, EPA does not accept a sticker; a signed statement or contract is required
Refrigerant exposed to an open flame or hot surface can decompose into toxic products. Which is one of them?
- Helium
- Phosgene
- Ozone
- Carbon monoxide only
In a household refrigerator with a capillary tube, the high-side access point is commonly installed on the:
- Drain line
- Suction line
- Discharge line or liquid line (for example, near the filter-drier)
- Evaporator plate
What is the passing score for a mail-in format Type I test?
- 75%
- 84%
- 90%
- 70%
Before using a torch to braze on a small appliance, you should:
- Fill the system with oxygen
- Leave the refrigerant in the system
- Open the windows only
- Recover the refrigerant and purge with nitrogen as needed
Answer key, explanations, and sources
A. Displace oxygen and cause suffocation (Type I safety)
Refrigerant vapor is heavier than air and can displace oxygen, causing asphyxiation, especially in low or enclosed spaces.
Source: EPA – Section 608 Test Topics
C. The high side, with the appliance compressor running (Small appliance recovery techniques)
With a working compressor, the compressor pushes refrigerant toward the high side, so passive recovery is usually done from the high side while running the compressor.
Source: EPA – Section 608 Test Topics
C. 5 pounds or less of refrigerant (Small appliance recovery requirements)
40 CFR 82.152 defines a small appliance as fully manufactured, charged and hermetically sealed in a factory with five pounds or less of refrigerant.
Source: 40 CFR 82.152 – Definitions
D. Refrigerant decomposition or acid in the system (Type I safety)
A burnout or refrigerant exposed to high heat can produce acids and acrid decomposition products. Ventilate and use PPE.
Source: EPA – Section 608 Test Topics
D. Evacuated (Small appliance recovery techniques)
Evacuating the bag or container first prevents air from contaminating the recovered refrigerant.
Source: EPA – Section 608 Test Topics
D. No, but they must use recovery equipment that meets EPA performance standards (Small appliance recovery requirements)
EPA says people recovering refrigerant from small appliances for disposal don't have to be certified, but the recovery equipment must meet the same performance standards and venting is still prohibited.
Source: EPA – Stationary Refrigeration Safe Disposal Requirements
B. Oxygen and compressor oil can explode under pressure (Type I safety)
Never use oxygen or compressed air. Oil and oxygen under pressure can explode; use dry nitrogen with a regulator.
Source: EPA – Section 608 Test Topics
A. Uses its own compressor and can recover whether or not the appliance compressor works (Small appliance recovery techniques)
Self-contained equipment has its own pump/compressor and stores refrigerant in a pressurized recovery cylinder, independent of the appliance compressor.
Source: 40 CFR 82.152 – Definitions
A. 90% with compressor running and 80% with it not running (Small appliance recovery requirements)
40 CFR 82.158 requires small-appliance recovery equipment to be certified as capable of recovering 90% with the test-stand compressor operating and 80% when it is not operating.
Source: 40 CFR 82.158 – Standards for recovery and/or recycling equipment
B. Eliminate ignition sources and ventilate the area (Type I safety)
Hydrocarbons are flammable (A3). Remove ignition sources, ventilate, and use tools and recovery equipment rated for flammable refrigerants.
Source: EPA – Refrigerant Safety (ASHRAE Standard 34 classes)
A. Only if it discharges into a non-pressurized recovery container (Small appliance recovery techniques)
EPA lists using a vacuum pump with a non-pressurized recovery container as a method for small appliances with inoperative compressors.
Source: EPA – Section 608 Test Topics
D. 80% (or 4 inches Hg vacuum) (Small appliance recovery requirements)
With a non-functioning compressor, the requirement is 80% recovery even with post-1993 equipment (or 4 inches Hg vacuum).
A. Should be kept separate and sent for reclamation or destruction (Type I safety)
Contaminated refrigerant should not be mixed with good refrigerant; it must be recovered and sent for reclamation or destruction if it can't be reclaimed.
D. The required recovery percentage is reached, or the appliance is evacuated to 4 inches Hg vacuum (Small appliance recovery techniques)
Use the recovery equipment according to the manufacturer's directions until the 80/90% requirement or the 4 in Hg vacuum alternative is met.
Source: EPA – Stationary Refrigeration Service Practice Requirements
D. No (Small appliance recovery requirements)
Appendix D states mail-in format Type I tests cannot be used toward Universal certification.
Source: 40 CFR Part 82 Subpart F, Appendix D – Standards for certifying programs
B. Flammability: keep ignition sources away (Type I safety)
R-600a is A3: lower toxicity but higher flammability. Ventilate and keep flames and sparks away. Its pressure is low (about 35 psig at 75°F).
Source: EPA – Refrigerant Safety (ASHRAE Standard 34 classes)
C. The system's standing pressure with its temperature on a PT chart (Small appliance recovery techniques)
EPA's Type I topics include using pressure and temperature to identify refrigerants and detect non-condensables. At equilibrium the pressure should match the PT chart at ambient temperature.
Source: EPA – Section 608 Test Topics
A. 4 inches of mercury vacuum (Small appliance recovery requirements)
40 CFR 82.156(b)(3) lets technicians satisfy the small-appliance requirement by evacuating to four inches of mercury vacuum.
C. Its hydrostatic test date, damage, rust, and a working valve (Type I safety)
Check DOT recovery cylinders for a current hydrostatic test date, physical damage, rust and valve condition, and never fill beyond 80% capacity.
Source: EPA – Section 608 Test Topics
D. A DOT-approved refillable recovery cylinder (Small appliance recovery techniques)
Self-contained recovery stores refrigerant under pressure, so it must go into a DOT-approved refillable recovery cylinder, never a disposable one.
Source: EPA – Section 608 Test Topics
D. No, EPA does not accept a sticker; a signed statement or contract is required (Small appliance recovery requirements)
EPA does not mandate or accept a sticker as verification. The final disposer needs a signed statement or a qualifying contract.
Source: EPA – Stationary Refrigeration Safe Disposal Requirements
B. Phosgene (Type I safety)
EPA's Type I safety topic covers decomposition products of refrigerants at high temperatures, which can include phosgene, hydrochloric acid and hydrofluoric acid.
Source: EPA – Section 608 Test Topics
C. Discharge line or liquid line (for example, near the filter-drier) (Small appliance recovery techniques)
In small appliances the high-side access valve is usually installed on the discharge or liquid line (often near the filter-drier). The compressor's process stub is normally low-side access, so with an inoperative compressor you need valves on both sides.
Source: EPA – Section 608 Test Topics
B. 84% (Small appliance recovery requirements)
Appendix D: the passing score for closed-book tests is 70%, while mail-in format Type I tests require 84%.
Source: 40 CFR Part 82 Subpart F, Appendix D – Standards for certifying programs
D. Recover the refrigerant and purge with nitrogen as needed (Type I safety)
Recover refrigerant before applying heat so it doesn't decompose into toxic gases. Flowing dry nitrogen while brazing also prevents oxidation.
Source: EPA – Section 608 Test Topics