Skip to content
TradeCert Prep
Free practice · Type I

Small appliance recovery techniques: Type I practice

27 published questions in this topic. Free Small appliance recovery techniques practice for EPA 608 Type I, with instant feedback, explanations and source links.

10 published questionsFeedback appears after each answer
Type I · Small appliance recovery techniquesQuestion 1 of 10

Recovery from a small appliance is complete when:

Answer choices for question 1

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery techniquesQuestion 2 of 10

Self-contained (active) recovery equipment used on small appliances:

Answer choices for question 2

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery techniquesQuestion 3 of 10

Which recovery cylinder is acceptable for self-contained recovery from a small appliance?

Answer choices for question 3

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery techniquesQuestion 4 of 10

In a household refrigerator with a capillary tube, the high-side access point is commonly installed on the:

Answer choices for question 4

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery techniquesQuestion 5 of 10

When you install a piercing-type access valve on a small appliance, what is good practice?

Answer choices for question 5

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery techniquesQuestion 6 of 10

A technician finds a household freezer at 75°F room temperature whose R-134a pressure matches the PT chart at 75°F. This suggests:

Answer choices for question 6

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery techniquesQuestion 7 of 10

A recovery cylinder at 75°F reads higher pressure than the PT chart value for its refrigerant at 75°F. This most likely means:

Answer choices for question 7

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery techniquesQuestion 8 of 10

Which techniques help recover refrigerant from a small appliance with an inoperative compressor using a passive device?

Answer choices for question 8

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery techniquesQuestion 9 of 10

Which refrigerant is the common HFC replacement for R-12 in household refrigerators?

Answer choices for question 9

Keyboard: A–D to choose · Enter to check

Type I · Small appliance recovery techniquesQuestion 10 of 10

Propane (R-290) in a stand-alone retail food refrigerator is, under the Section 608 venting rules:

Answer choices for question 10

Keyboard: A–D to choose · Enter to check

Ready for a full-length run?

Take a free timed mock for Type I or the full Universal: real section length and pass mark, instant score, no signup.

About this topic

Recovery methods and equipment used with small appliances. This page draws 10 questions from the 27 sourced Type I questions we have on small appliance recovery techniques; each answer explains why and links to the rule it tests.

On the real test: Every Type I section on the real exam has 25 questions drawn across all Type I topics, and you need 18 of 25 (70%) on the closed-book test. Our bank has 27 practice questions on this topic. Expect questions like: “With system-dependent recovery, refrigerant is commonly captured in a:” and “At the conclusion of service on a small appliance, solderless (piercing-type) access fittings should be:”

Key facts to remember

  • System-dependent recovery limit Full charge of 15 lb or less (unless a permanent pump-out unit) (source)
  • Which refrigerant is the common HFC replacement for R-12 in household refrigerators R-134a (source)
  • Recovery from a small appliance is complete when The required recovery percentage is reached, or the appliance is evacuated to 4 inches Hg vacuum (source)
  • A technician finds a household freezer at 75°F room temperature whose R-134a pressure matches the PT chart at The system contains R-134a with no significant non-condensables (source)

Keep studying