Leak repair requirements: Type II practice

19 published questions in this topic. Free Leak repair requirements practice for EPA 608 Type II, with instant feedback, explanations and source links.

10 published questionsFeedback appears after each answer
Type II · Leak repair requirementsQuestion 1 of 10

If an industrial process shutdown is needed to repair a leak, the repair period becomes:

Answer choices for question 1

Keyboard: A–D to choose · Enter to check

Type II · Leak repair requirementsQuestion 2 of 10

Leak repair records (dates, amount added, leak rate) generally must be kept for:

Answer choices for question 2

Keyboard: A–D to choose · Enter to check

Type II · Leak repair requirementsQuestion 3 of 10

For a comfort cooling appliance that exceeded its trigger rate, leak inspections must be done:

Answer choices for question 3

Keyboard: A–D to choose · Enter to check

Type II · Leak repair requirementsQuestion 4 of 10

Once an appliance is found leaking above the trigger rate, leaks generally must be repaired within:

Answer choices for question 4

Keyboard: A–D to choose · Enter to check

Type II · Leak repair requirementsQuestion 5 of 10

Under the annualizing method, if 10 lb is added to a 100 lb appliance 73 days after the last addition, the leak rate is about:

Answer choices for question 5

Keyboard: A–D to choose · Enter to check

Type II · Leak repair requirementsQuestion 6 of 10

Who must perform the required leak inspections?

Answer choices for question 6

Keyboard: A–D to choose · Enter to check

Type II · Leak repair requirementsQuestion 7 of 10

What is the leak-rate trigger for commercial refrigeration appliances over a 12-month period?

Answer choices for question 7

Keyboard: A–D to choose · Enter to check

Type II · Leak repair requirementsQuestion 8 of 10

A supermarket refrigeration rack system would fall under which leak-rate category?

Answer choices for question 8

Keyboard: A–D to choose · Enter to check

Type II · Leak repair requirementsQuestion 9 of 10

The leak rate is calculated each time refrigerant is:

Answer choices for question 9

Keyboard: A–D to choose · Enter to check

Type II · Leak repair requirementsQuestion 10 of 10

'Mothballing' a leaking appliance means:

Answer choices for question 10

Keyboard: A–D to choose · Enter to check

Ready for a full-length run?

Take a free timed mock for Type II or the full Universal: real section length and pass mark, instant score, no signup.

About this topic

Leak repair requirements and timelines. This page draws 10 questions from the 19 sourced Type II questions we have on leak repair requirements; each answer explains why and links to the rule it tests.

On the real test: Every Type II section on the real exam has 25 questions drawn across all Type II topics, and you need 18 of 25 (70%) on the closed-book test. Our bank has 19 practice questions on this topic. Expect questions like: “What is the leak-rate trigger for comfort cooling appliances?” and “A supermarket refrigeration rack system would fall under which leak-rate category?”

Key facts to remember

  • Leak rate trigger: IPR 30% (source)
  • Leak rate trigger: commercial refrigeration 20% (source)
  • Leak rate trigger: comfort cooling 10% (source)
  • Repair deadline 30 days (120 with an IPR shutdown) (source)