Recovery techniques: Type II practice

12 published questions in this topic. Free Recovery techniques practice for EPA 608 Type II, with instant feedback, explanations and source links.

10 published questionsFeedback appears after each answer
Type II · Recovery techniquesQuestion 1 of 10

The push-pull method generally should not be used when:

Answer choices for question 1

Keyboard: A–D to choose · Enter to check

Type II · Recovery techniquesQuestion 2 of 10

The 'push-pull' recovery method is used to:

Answer choices for question 2

Keyboard: A–D to choose · Enter to check

Type II · Recovery techniquesQuestion 3 of 10

After reaching the required recovery vacuum, a technician should wait a few minutes to see if the pressure rises. A rise indicates:

Answer choices for question 3

Keyboard: A–D to choose · Enter to check

Type II · Recovery techniquesQuestion 4 of 10

When using a recovery or recycling machine with a different refrigerant, to reduce cross-contamination you should:

Answer choices for question 4

Keyboard: A–D to choose · Enter to check

Type II · Recovery techniquesQuestion 5 of 10

Removing Schrader valve cores and using core-removal tools during recovery:

Answer choices for question 5

Keyboard: A–D to choose · Enter to check

Type II · Recovery techniquesQuestion 6 of 10

System-dependent recovery equipment is prohibited on appliances containing more than:

Answer choices for question 6

Keyboard: A–D to choose · Enter to check

Type II · Recovery techniquesQuestion 7 of 10

Which practice speeds up recovery?

Answer choices for question 7

Keyboard: A–D to choose · Enter to check

Type II · Recovery techniquesQuestion 8 of 10

Where is liquid refrigerant typically recovered from in a high-pressure system with a receiver?

Answer choices for question 8

Keyboard: A–D to choose · Enter to check

Type II · Recovery techniquesQuestion 9 of 10

When recovering from a system whose compressor does not run, recovery should be done from:

Answer choices for question 9

Keyboard: A–D to choose · Enter to check

Type II · Recovery techniquesQuestion 10 of 10

Why is a recovery cylinder sometimes placed in ice water during recovery?

Answer choices for question 10

Keyboard: A–D to choose · Enter to check

Ready for a full-length run?

Take a free timed mock for Type II or the full Universal: real section length and pass mark, instant score, no signup.

About this topic

Recovery equipment and techniques for covered appliances. This page draws 10 questions from the 12 sourced Type II questions we have on recovery techniques; each answer explains why and links to the rule it tests.

On the real test: Every Type II section on the real exam has 25 questions drawn across all Type II topics, and you need 18 of 25 (70%) on the closed-book test. Our bank has 12 practice questions on this topic. Expect questions like: “When using a recovery or recycling machine with a different refrigerant, to reduce cross-contamination you should:” and “The 'push-pull' recovery method is used to:”

Key facts to remember

  • The push-pull method generally should not be used when The system holds less than about 15 lb, or has no accessible liquid (e.g., some heat pumps with reversing valves) (source)
  • System-dependent recovery equipment is prohibited on appliances containing more than 15 lb (source)