Skip to content
TradeCert Prep
Free practice · Type II

Refrigeration & components: Type II practice

20 published questions in this topic. Free Refrigeration & components practice for EPA 608 Type II, with instant feedback, explanations and source links.

10 published questionsFeedback appears after each answer
Type II · Refrigeration & componentsQuestion 1 of 10

Using a PT chart, a technician reads 120 psig on a cylinder of R-22. To express this in psia, they should:

Answer choices for question 1

Keyboard: A–D to choose · Enter to check

Type II · Refrigeration & componentsQuestion 2 of 10

Which refrigerants are listed by EPA as examples used in high-pressure appliances?

Answer choices for question 2

Keyboard: A–D to choose · Enter to check

Type II · Refrigeration & componentsQuestion 3 of 10

An R-22 system has a condensing (saturation) temperature of 120°F and a liquid line temperature of 110°F. The subcooling is:

Answer choices for question 3

Keyboard: A–D to choose · Enter to check

Type II · Refrigeration & componentsQuestion 4 of 10

The refrigerant in the discharge line is:

Answer choices for question 4

Keyboard: A–D to choose · Enter to check

Type II · Refrigeration & componentsQuestion 5 of 10

The refrigerant in the liquid line is:

Answer choices for question 5

Keyboard: A–D to choose · Enter to check

Type II · Refrigeration & componentsQuestion 6 of 10

Many new residential split systems that once used R-410A now ship with which refrigerant?

Answer choices for question 6

Keyboard: A–D to choose · Enter to check

Type II · Refrigeration & componentsQuestion 7 of 10

A high-pressure system has frost or ice on the evaporator and low suction pressure. A possible cause is:

Answer choices for question 7

Keyboard: A–D to choose · Enter to check

Type II · Refrigeration & componentsQuestion 8 of 10

Hydrocarbon refrigerants such as propane are:

Answer choices for question 8

Keyboard: A–D to choose · Enter to check

Type II · Refrigeration & componentsQuestion 9 of 10

At 75°F, about what is the saturation pressure of R-32?

Answer choices for question 9

Keyboard: A–D to choose · Enter to check

Type II · Refrigeration & componentsQuestion 10 of 10

Why should you not open the system or add refrigerant before identifying the refrigerant in it?

Answer choices for question 10

Keyboard: A–D to choose · Enter to check

Ready for a full-length run?

Take a free timed mock for Type II or the full Universal: real section length and pass mark, instant score, no signup.

About this topic

Refrigeration systems and component fundamentals. This page draws 10 questions from the 20 sourced Type II questions we have on refrigeration & components; each answer explains why and links to the rule it tests.

On the real test: Every Type II section on the real exam has 25 questions drawn across all Type II topics, and you need 18 of 25 (70%) on the closed-book test. Our bank has 20 practice questions on this topic. Expect questions like: “Which refrigerants are listed by EPA as examples used in high-pressure appliances?” and “Using a PT chart, a technician reads 120 psig on a cylinder of R-22. To express this in psia, they should:”

Key facts to remember

  • Which refrigerants are listed by EPA as examples used in high-pressure appliances R-22, R-407C and R-410A (source)
  • Using a PT chart, a technician reads 120 psig on a cylinder of R-22. To express this in psia, they should Add 14.7 → 134.7 psia (source)
  • Using the PT chart, R-410A at a saturation temperature of 40°F is about 118 psig. If the suction line temperat 10°F (source)
  • An R-22 system has a condensing (saturation) temperature of 120°F and a liquid line temperature of 110°F. The 10°F (source)

Keep studying