Leak detection: Type III practice

13 published questions in this topic. Free Leak detection practice for EPA 608 Type III, with instant feedback, explanations and source links.

10 published questionsFeedback appears after each answer
Type III · Leak detectionQuestion 1 of 10

Leak inspections are required for low-pressure appliances that exceed the applicable leak rate. They must be performed by:

Answer choices for question 1

Keyboard: A–D to choose · Enter to check

Type III · Leak detectionQuestion 2 of 10

Which leak test method is preferred for a low-pressure system?

Answer choices for question 2

Keyboard: A–D to choose · Enter to check

Type III · Leak detectionQuestion 3 of 10

Low-pressure chillers (e.g., R-123) operate with the evaporator below atmospheric pressure. Because of this, leaks usually cause:

Answer choices for question 3

Keyboard: A–D to choose · Enter to check

Type III · Leak detectionQuestion 4 of 10

Before leak testing a low-pressure chiller with nitrogen, you should first:

Answer choices for question 4

Keyboard: A–D to choose · Enter to check

Type III · Leak detectionQuestion 5 of 10

To check whether water tubes in a chiller are leaking, a technician can:

Answer choices for question 5

Keyboard: A–D to choose · Enter to check

Type III · Leak detectionQuestion 6 of 10

If nitrogen is used to leak test a low-pressure centrifugal chiller, the maximum test pressure is:

Answer choices for question 6

Keyboard: A–D to choose · Enter to check

Type III · Leak detectionQuestion 7 of 10

The rupture disc on a low-pressure chiller's evaporator is typically rated at:

Answer choices for question 7

Keyboard: A–D to choose · Enter to check

Type III · Leak detectionQuestion 8 of 10

After using nitrogen to pressurize a low-pressure chiller for a leak test, the nitrogen:

Answer choices for question 8

Keyboard: A–D to choose · Enter to check

Type III · Leak detectionQuestion 9 of 10

A low-pressure chiller's purge unit runs much more than normal. The technician should first suspect:

Answer choices for question 9

Keyboard: A–D to choose · Enter to check

Type III · Leak detectionQuestion 10 of 10

A sign of leakage into a low-pressure system is:

Answer choices for question 10

Keyboard: A–D to choose · Enter to check

Ready for a full-length run?

Take a free timed mock for Type III or the full Universal: real section length and pass mark, instant score, no signup.

About this topic

Leak detection requirements and methods. This page draws 10 questions from the 13 sourced Type III questions we have on leak detection; each answer explains why and links to the rule it tests.

On the real test: Every Type III section on the real exam has 25 questions drawn across all Type III topics, and you need 18 of 25 (70%) on the closed-book test. Our bank has 13 practice questions on this topic. Expect questions like: “If nitrogen is used to leak test a low-pressure centrifugal chiller, the maximum test pressure is:” and “Why is leak-test pressure on a low-pressure chiller limited?”

Key facts to remember

  • Leak-test pressure limit No more than 10 psig (source)
  • Rupture disc Relieves at 15 psig (source)
  • If nitrogen is used to leak test a low-pressure centrifugal chiller, the maximum test pressure is 10 psig (source)
  • Why is leak-test pressure on a low-pressure chiller limited To protect the rupture disc, which is typically set at 15 psig (source)