Purge units & refrigeration: Type III practice

16 published questions in this topic. Free Purge units & refrigeration practice for EPA 608 Type III, with instant feedback, explanations and source links.

10 published questionsFeedback appears after each answer
Type III · Purge units & refrigerationQuestion 1 of 10

The low-pressure chiller component that holds the boiling refrigerant and cools the chilled water is the:

Answer choices for question 1

Keyboard: A–D to choose · Enter to check

Type III · Purge units & refrigerationQuestion 2 of 10

Pressure in a low-pressure chiller is often expressed in inches of mercury vacuum because:

Answer choices for question 2

Keyboard: A–D to choose · Enter to check

Type III · Purge units & refrigerationQuestion 3 of 10

R-514A, listed by EPA for centrifugal chillers, has which ASHRAE safety class?

Answer choices for question 3

Keyboard: A–D to choose · Enter to check

Type III · Purge units & refrigerationQuestion 4 of 10

Which of these is a low-pressure refrigerant listed in EPA's definition?

Answer choices for question 4

Keyboard: A–D to choose · Enter to check

Type III · Purge units & refrigerationQuestion 5 of 10

R-11 at 32°F has a saturation pressure of about:

Answer choices for question 5

Keyboard: A–D to choose · Enter to check

Type III · Purge units & refrigerationQuestion 6 of 10

Why does R-123 need careful handling compared with R-22 or R-410A?

Answer choices for question 6

Keyboard: A–D to choose · Enter to check

Type III · Purge units & refrigerationQuestion 7 of 10

At normal room temperature (about 77°F), an R-123 system that is off typically sits at:

Answer choices for question 7

Keyboard: A–D to choose · Enter to check

Type III · Purge units & refrigerationQuestion 8 of 10

Where does a purge unit typically take its sample from on a centrifugal chiller?

Answer choices for question 8

Keyboard: A–D to choose · Enter to check

Type III · Purge units & refrigerationQuestion 9 of 10

A purge unit vents mostly refrigerant instead of air. This means:

Answer choices for question 9

Keyboard: A–D to choose · Enter to check

Type III · Purge units & refrigerationQuestion 10 of 10

What is the purpose of a purge unit on a low-pressure chiller?

Answer choices for question 10

Keyboard: A–D to choose · Enter to check

Ready for a full-length run?

Take a free timed mock for Type III or the full Universal: real section length and pass mark, instant score, no signup.

About this topic

Purge units and low-pressure refrigeration systems. This page draws 10 questions from the 16 sourced Type III questions we have on purge units & refrigeration; each answer explains why and links to the rule it tests.

On the real test: Every Type III section on the real exam has 25 questions drawn across all Type III topics, and you need 18 of 25 (70%) on the closed-book test. Our bank has 16 practice questions on this topic. Expect questions like: “Which refrigerant is commonly used in low-pressure centrifugal chillers today?” and “Which of these is a low-pressure refrigerant listed in EPA's definition?”

Key facts to remember

  • Which refrigerant is commonly used in low-pressure centrifugal chillers today R-123 (source)
  • Which of these is a low-pressure refrigerant listed in EPA's definition R-245fa (source)
  • R-11 at 32°F has a saturation pressure of about 18 inches Hg vacuum (source)
  • Why does R-123 need careful handling compared with R-22 or R-410A It is in ASHRAE safety group B1 (higher toxicity), so exposure limits are lower (source)