Last reviewed: November 24, 2026
| Fact | Value | Source |
|---|---|---|
| Core and type sections | 25 Core questions plus 25 questions for each selected type section. | 40 CFR Part 82, Subpart F, Appendix D |
| Universal test | 100 questions: 25 Core and 25 each from Types I, II, and III. | 40 CFR Part 82, Subpart F, Appendix D |
| Passing mark | 70% (18 of 25) in each closed-book section. | 40 CFR Part 82, Subpart F, Appendix D |
| Mail-in Type I | 84% (21 of 25); this format cannot be used toward Universal. | 40 CFR Part 82, Subpart F, Appendix D |
| Proctored sections | Type II, Type III, and Universal are closed-book and proctored. | 40 CFR Part 82, Subpart F, Appendix D |
| Certification validity | Section 608 technician certification credentials do not expire. | EPA — Section 608 Technician Certification Requirements |
| 2026 question-bank update | Updated August 28, 2026; old-bank exams may be given only through January 1, 2027. | ESCO Institute — EPA Section 608 certification |
| Small appliance | Factory-manufactured, charged, hermetically sealed, with 5 lb or less of refrigerant. | 40 CFR 82.152 — Definitions |
| Section 608 leak triggers | For appliances with 50 lb or more of ozone-depleting refrigerant: 10% comfort cooling and other, 20% commercial refrigeration, 30% industrial process refrigeration. | 40 CFR 82.157 — Appliance maintenance and leak repair |
| Separate HFC leak rule | Since January 1, 2026, 40 CFR Part 84 covers certain HFC appliances with 15 lb or more; it is not part of the Section 608 exam. | 40 CFR 84.106 — HFC leak repair requirements |
| System-dependent recovery | Generally cannot be used on an appliance with a full charge over 15 lb unless permanently attached as a pump-out unit. | 40 CFR 82.156 — Proper evacuation of refrigerant |
| Evacuation levels | See the cited evacuation table on the EPA 608 cheat sheet. | EPA 608 cheat sheet — evacuation table |
Our question bank in numbers
Counts and citation shares below are calculated from currently published EPA 608 questions. Citation percentages use each section or topic's published question count as the denominator.
Most recent question update in the database: Nov 24, 2026.
| Section | Questions | eCFR citations | EPA page citations |
|---|---|---|---|
| Core | 157 | 19 (12.1%) | 126 (80.3%) |
| Type I | 66 | 16 (24.2%) | 49 (74.2%) |
| Type II | 92 | 24 (26.1%) | 63 (68.5%) |
| Type III | 78 | 15 (19.2%) | 63 (80.8%) |
Counts by topic
| Section and topic | Questions | eCFR citations | EPA page citations |
|---|---|---|---|
| Core: Ozone depletion & environmental impact | 16 | 0 (0.0%) | 16 (100.0%) |
| Core: Clean Air Act & Montreal Protocol | 15 | 1 (6.7%) | 12 (80.0%) |
| Core: Section 608 regulations | 30 | 14 (46.7%) | 16 (53.3%) |
| Core: Substitute refrigerants & oils | 12 | 0 (0.0%) | 12 (100.0%) |
| Core: Refrigeration cycle & gauges | 15 | 0 (0.0%) | 15 (100.0%) |
| Core: The three Rs: recover, recycle, reclaim | 10 | 0 (0.0%) | 10 (100.0%) |
| Core: Recovery & dehydration | 11 | 0 (0.0%) | 11 (100.0%) |
| Core: Safety | 10 | 0 (0.0%) | 10 (100.0%) |
| Core: Shipping & cylinders | 10 | 0 (0.0%) | 10 (100.0%) |
| Core: A2L, A3 & low-GWP refrigerants | 28 | 4 (14.3%) | 14 (50.0%) |
| Type I: Small appliance recovery requirements | 25 | 14 (56.0%) | 11 (44.0%) |
| Type I: Small appliance recovery techniques | 27 | 2 (7.4%) | 25 (92.6%) |
| Type I: Type I safety | 14 | 0 (0.0%) | 13 (92.9%) |
| Type II: Leak detection | 13 | 6 (46.2%) | 7 (53.8%) |
| Type II: Leak repair requirements | 19 | 10 (52.6%) | 9 (47.4%) |
| Type II: Recovery techniques | 12 | 1 (8.3%) | 11 (91.7%) |
| Type II: Evacuation requirements | 16 | 4 (25.0%) | 12 (75.0%) |
| Type II: Refrigeration & components | 20 | 2 (10.0%) | 14 (70.0%) |
| Type II: Type II safety | 12 | 1 (8.3%) | 10 (83.3%) |
| Type III: Leak detection | 13 | 1 (7.7%) | 12 (92.3%) |
| Type III: Leak repair requirements | 10 | 6 (60.0%) | 4 (40.0%) |
| Type III: Recovery & recharging techniques | 17 | 0 (0.0%) | 17 (100.0%) |
| Type III: Evacuation requirements | 12 | 5 (41.7%) | 7 (58.3%) |
| Type III: Purge units & refrigeration | 16 | 3 (18.8%) | 13 (81.3%) |
| Type III: Type III safety | 10 | 0 (0.0%) | 10 (100.0%) |
Frequently asked questions
Do the HFC leak repair rules appear on the EPA 608 exam?
No. The HFC requirements in 40 CFR Part 84 are a separate AIM Act rule. Section 608 leak repair under 40 CFR 82.157 covers appliances with 50 lb or more of ozone-depleting refrigerant.
Sources
- 40 CFR Part 82, Subpart F, Appendix D
- EPA — Section 608 Technician Certification Requirements
- EPA — Section 608 Test Topics
- ESCO Institute — EPA Section 608 certification
- 40 CFR 82.152 — Definitions
- 40 CFR 82.156 — Proper evacuation of refrigerant
- 40 CFR 82.157 — Appliance maintenance and leak repair
- 40 CFR 84.106 — HFC leak repair requirements
Related: EPA 608 cheat sheet, 2026 exam changes, and free Core practice.