Values computed with CoolProp 8.1.0 (open-source thermophysical property library; Bell et al., Ind. Eng. Chem. Res. 2014) using Helmholtz-energy equations of state; blends modeled from their nominal ASHRAE 34 mass compositions. A few points near the top of the range were interpolated. For field work, confirm against the refrigerant manufacturer's PT chart.
R-290 saturation table
| Temp °F | Temp °C | Saturation (psig) |
|---|---|---|
| -40 °F | -40.0 °C | 1.4 psig |
| -35 °F | -37.2 °C | 3.4 psig |
| -30 °F | -34.4 °C | 5.7 psig |
| -25 °F | -31.7 °C | 8.1 psig |
| -20 °F | -28.9 °C | 10.7 psig |
| -15 °F | -26.1 °C | 13.6 psig |
| -10 °F | -23.3 °C | 16.7 psig |
| -5 °F | -20.6 °C | 20.1 psig |
| 0 °F | -17.8 °C | 23.7 psig |
| 5 °F | -15.0 °C | 27.6 psig |
| 10 °F | -12.2 °C | 31.8 psig |
| 15 °F | -9.4 °C | 36.3 psig |
| 20 °F | -6.7 °C | 41.1 psig |
| 25 °F | -3.9 °C | 46.3 psig |
| 30 °F | -1.1 °C | 51.8 psig |
| 35 °F | 1.7 °C | 57.7 psig |
| 40 °F | 4.4 °C | 63.9 psig |
| 45 °F | 7.2 °C | 70.6 psig |
| 50 °F | 10.0 °C | 77.6 psig |
| 55 °F | 12.8 °C | 85.1 psig |
| 60 °F | 15.6 °C | 93.0 psig |
| 65 °F | 18.3 °C | 101.4 psig |
| 70 °F | 21.1 °C | 110.2 psig |
| 75 °F | 23.9 °C | 119.5 psig |
| 80 °F | 26.7 °C | 129.3 psig |
| 85 °F | 29.4 °C | 139.7 psig |
| 90 °F | 32.2 °C | 150.5 psig |
| 95 °F | 35.0 °C | 161.9 psig |
| 100 °F | 37.8 °C | 173.9 psig |
| 105 °F | 40.6 °C | 186.5 psig |
| 110 °F | 43.3 °C | 199.6 psig |
| 115 °F | 46.1 °C | 213.4 psig |
| 120 °F | 48.9 °C | 227.8 psig |
| 125 °F | 51.7 °C | 242.9 psig |
| 130 °F | 54.4 °C | 258.7 psig |
| 135 °F | 57.2 °C | 275.1 psig |
| 140 °F | 60.0 °C | 292.3 psig |
| 145 °F | 62.8 °C | 310.2 psig |
| 150 °F | 65.6 °C | 328.9 psig |
R-290 chart FAQs
What is the pressure of R-290 at 75°F?
At 75°F, R-290 is approximately 119.5 psig.
What is the boiling temperature of R-290 at 0 psig?
Zero gauge pressure is outside the published temperature range for R-290.
Does R-290 have temperature glide?
R-290 is single-component in this chart, so its bubble and dew pressures are the same at each listed temperature.
What is R-290 used for?
Small self-contained units designed for it (e.g., some room ACs and commercial cases). R-290 is a Hydrocarbon with ASHRAE safety class A3 and a 100-year GWP of 3.3. Acceptable only in specific new equipment designed for it; unacceptable for retrofitting split AC systems.
Cite this chart: R-290 pressure-temperature chart, TradeCert Prep, computed with CoolProp 8.1.0, retrieved November 26, 2026. License CC BY 4.0.